Vol. 6 No. 1 (2027): Issue In Progress
Research Articles
-
Article: 62Published: 17.11.2026 pp. 1-32
Warm-starting conventional solver for ACOPF prediction using Modified Seagull Optimization Algorithm and physics-informed spatiotemporal graph neural network
AbstractThe penetration of renewable energy has intensified the computational challenges associated with solving the AC Optimal Power Flow (ACOPF) problem. The Newton–Raphson (NR) solver is highly sensitive to initialization and may exhibit slow convergence under dynamic conditions. This research proposes a physics-informed spatiotemporal graph neural network (PIStGNN) framework to generate initial conditions for warm-starting the NR solver to improve computational efficiency. The model integrates graph convolutional networks to capture system topology and recurrent architectures (LSTM/GRU) to model temporal variability. A physics-informed loss function enforces power flow constraints, while a Modified Seagull Optimization Algorithm (MoSOA) enhances hyperparameter tuning. The proposed method is compared with DC and flat start warm-start strategies for IEEE 33-, 57-, and 118-bus systems. The results show that the PIStGNN method maintains high accuracy, with MAE values of 0.0126, 0.0446, and 0.0063 for IEEE 33-, 57-, and 118-bus systems respectively. The proposed PIStGNN initialization maintains the lowest runtime across all test systems. On average, the proposed method achieved 1.3–18% computational time reduction compared to conventional initialization techniques. Overall convergence is faster even with more iterations. The high-quality starting point makes the path to convergence more stable. The physics-informed learning provides efficient and scalable ACOPF solutions.
-
Article: 66Published: 17.11.2026 pp. 1-28
An Improved Electromagnetism-like Algorithm for Gaussian Process Hyperparameter Optimization in Remaining Useful Life Prediction of Electrolytic Capacitors
AbstractThis paper introduces an innovative optimization procedure to enhance gaussian process regression (GPR) for hyperparameter tuning. The technique estimates the remaining useful life (RUL) of electrolytic capacitors under electrical overstress conditions. The traditional electromagnetism-like (EM) optimization technique suffers premature convergence and insufficient exploitation near local optimal solutions. It also suffers ineffective charge relocation within high-dimensional search spaces. To address these limitations, the adaptive chaotic opposition-based learning electromagnetism-like (ACOEM) algorithm is proposed. The new algorithm incorporates three techniques to overcome these challenges: opposition-based learning to increase initial population size and speed up the optimization process; chaotic map-based scaling of forces to strike a balance between exploration and exploitation; and lévy flights to avoid local minima. The ACOEM optimizer fine-tunes the hyperparameters of the GPR kernel by minimizing the negative log marginal likelihood (NLML) objective function. The proposed ACOEM-GPR predictor is successfully applied to National Aeronautics and Space Administration (NASA’s) electrochemical capacitor electrical overstress dataset based on three (3) stress levels: 10V, 12V and 14V. Compared to the vanilla GPR predictor, ACOEM-GPR exhibited superior performance in terms of the correlation coefficient , improving from 0.3015 to 0.7482 for 10V stress and from 0.5615 to 0.8921 for 14V stress. Additionally, the ACOEM-GPR method showed significant improvements in mean squared error (MSE) reducing the MSE from 9458 to 3410 and root mean squared error (RMSE) from 97.3 to 58.4 at 10V. ACOEM-GPR is proven to produce accurate and robust RUL predictions allowing for effective predictive maintenance of power converter capacitors.
-
Article: 73Published: 17.11.2026 pp. 1-19
Bankability Assessment of Lithium-ion and Vanadium Redox Flow Batteries in Kenyan Hybrid Renewable Energy Systems
AbstractReliable and affordable electricity remains essential for rural development; however, in Sub-Saharan Africa (SSA), particularly Kenya, the major barrier to scalable rural electrification is increasingly the bankability gap, where technically feasible Hybrid Renewable Energy Systems (HRES) fail to attract sustainable investment. This study evaluates how battery storage technology selection influences investment viability by comparing lithium-ion (Li-ion) and vanadium redox flow battery (VRFB) systems in a rural Kenyan HRES. An integrated framework combining Homer Pro optimization, project-level financial modelling, Life Cycle Assessment (LCA), and AHP-based Multi-Criteria Decision Analysis (MCDA) was applied to assess techno-economic performance, environmental sustainability, and investor attractiveness. Results show that Li-ion systems achieve stronger short-term financial bankability, with lower Levelized Cost of Storage (LCOS) of KSh 23.17/kWh compared to KSh 28.32/kWh for VRFB systems, alongside higher baseline Investor Attractiveness Index (IAI). However, Li-ion technologies exhibit higher lifecycle environmental burden and replacement risk. In contrast, VRFB systems demonstrate lower emissions, longer operational lifetime, and stronger suitability under concessional and sustainability-oriented financing structures. Sensitivity analysis reveals that battery bankability depends not only on technical performance but also on financing structure, discount rate, and investor class.
-
Article: 71Published: 17.11.2026 pp. 1-25
Feasibility Analysis of Hybrid Green Power Generation System for Healthcare Institutions
AbstractReliable and sustainable electricity supply is essential for healthcare facilities, where power interruptions can compromise critical medical services and patient safety. This study evaluates the techno-economic and environmental feasibility of a grid-connected hybrid green power generation system for healthcare institutions using the HOMER Pro optimization software. The proposed configuration comprises a 50 kW solar photovoltaic (PV) array, a 50 kW biogas generator, a 10 kW fuel cell integrated with a 10 kW electrolyzer and a 10 kg hydrogen storage tank, a 50 kW power converter, and grid connectivity. Simulation results demonstrate that the optimal hybrid system is both economically and technically viable, achieving an NPC of $168,314 and a COE of $0.156/kWh. The system generated sufficient electricity to export approximately 128,194 kWh/year of surplus power to the utility grid while purchasing only 19,239 kWh/year, indicating high energy generation capability, operational flexibility, and reduced dependence on grid electricity. Environmental assessment further revealed a renewable energy fraction of 93.2% with significantly reduced CO₂ emissions, highlighting the system's potential to mitigate environmental impacts. Sensitivity analysis confirmed that the proposed configuration remains economically attractive under a wide range of technical and financial uncertainties, demonstrating its robustness and resilience.
-
Article: 82Published: 17.11.2026 pp. 1-15
Analysis of Power Spectral Density as a Diagnostic Tool in PEM Fuel Cells with Pulsed Loads
AbstractThe analysis of fuel cell current power spectral density (PSD) of a Horizon H-100 proton-exchange membrane (PEM) fuel cell stack operating with a pulsed load is presented. Fuel cell current fluctuations can be used as a reliable diagnostic tool for the PEM fuel cell. Analysis of low-frequency flicker noise in a PEM fuel cell can provide a highly sensitive diagnostic tool for detecting degradation and classifying the operating state of the fuel cell. The PSD of the fuel cell current can be used as a statistical descriptor in the frequency domain. The slope α of the PSD of the fuel cell current can be monitored non-invasively to track the operating state and degradation of the fuel cell. The results from experimental tests are presented to illustrate that the value of α can be monitored to detect abnormal operation in the H-100 PEM fuel cell.
-
Article: 85Published: 17.11.2026 pp. 1-34
Adaptive Neighborhood Grid-Boundary Multi-Objective Mayfly Algorithm for Improved Pareto Front Approximation
AbstractMulti-objective optimization algorithms are widely used for solving engineering design problems involving conflicting objectives. The Multi-Objective Mayfly Algorithm (MOMA) is a promising swarm-based optimizer, but its performance can be limited by fixed search parameters, premature convergence, weak archive distribution, and loss of extreme trade-off solutions during archive truncation. This paper proposes an Adaptive Neighborhood Grid-Boundary Multi-Objective Mayfly Algorithm (ANGB-MOMA) to improve the convergence and diversity behavior of the original MOMA. The proposed method introduces four mechanisms: adaptive parameter control, neighborhood-guided leader selection, grid-based archive and leader selection, and boundary-preserving archive truncation. The algorithm was evaluated using ZDT and DTLZ benchmark functions and compared with Original MOMA, Levy-flight MOMA, Stochastic-inertia MOMA, NSGA-II, MOPSO, and MOEA/D. The experimental study also included ablation analysis, parameter sensitivity analysis, Holm-corrected Wilcoxon statistical tests, metric reproducibility settings, and runtime assessment. The results show that ANGB-MOMA significantly improves the original MOMA and related MOMA variants on most tested functions. Strong improvements were observed on ZDT1, ZDT2, ZDT5, ZDT6, DTLZ4, and DTLZ7, with particularly large IGD+ reductions on ZDT5 and ZDT6. ANGB-MOMA also achieved the best overall performance on DTLZ4 among all compared algorithms. However, the comparison shows that the proposed method is not universally superior to established optimizers, as MOPSO and MOEA/D performed better on some discontinuous, discrete, and multimodal benchmark cases. The results therefore support ANGB-MOMA as a reproducible and effective improvement to the MOMA framework, while also identifying ZDT3 and ZDT4 as important limitation cases for future development.
-
Article: 87Published: 17.11.2026 pp. 1-20
Optimal Capacitor Placement in Voltage-Dependent Distribution Networks Using Hybrid PSO–MILP: Case Study: Murang’a 11 kV Distribution Feeder, Kenya
AbstractThis paper presents a hybrid optimization methodology for optimal capacitor placement in radial distribution networks with voltage-dependent loads. The proposed approach employs Particle Swarm Optimization (PSO) for location selection and Mixed Integer Linear Programming (MILP) for discrete sizing, simultaneously minimizing active power losses, voltage deviation and equipment investment cost. The methodology incorporates the ZIP (constant impedance–constant current–constant power) load model and is validated against ETAP commercial software. Application to the Murang’a 11 kV distribution feeder in Kenya (253 buses, 69 km, 2,434 kW peak demand) identified a 450 kvar capacitor at Bus 115 as the optimal solution, reducing medium-voltage violations from 125 to 11 buses (91.2% reduction) while improving the power factor from 96.06% to 99.16%. The algorithm achieved convergence with an average execution time of 42.3 seconds on a standard desktop environment. When benchmarked against a standalone Genetic Algorithm, the hybrid PSO–MILP achieved superior solution quality (mean annual cost of USD 93,061 vs. USD 93,287), 38% faster convergence, and less than half the solution dispersion (standard deviation of USD 124.8 vs. USD 241.6). Statistical validation through 30 independent PSO runs confirmed algorithmic robustness with a coefficient of variation of 0.13%. The study quantifies the impact of voltage-dependent loads on capacitor performance and demonstrates the voltage compliance versus loss minimization trade-off characteristic of high R/X ratio feeders.
-
Article: 95Published: 17.11.2026 pp. 1-19
Rolling-horizon optimization of grid-tied PV–BESS for tariff savings, apparent-demand reduction, and critical-load survivability: A Tanzanian university case study
AbstractThis work presents a measurement-based techno-economic and reliability framework for sizing and dispatching a behind-the-meter photovoltaic and battery energy storage system (PV–BESS) at Mbeya University of Science and Technology (MUST), Tanzania. The analysis uses 26,280 measured, audited, timestamp-synchronized 20-minute active/reactive load data. The PV-generation profile was derived from historical global horizontal irradiance (GHI) time-series data using a validated PV system simulation framework, then synchronized with the measured demand series. Reliability is assessed using a 50-event outage calendar compiled from verified TANESCO interruption records and cross-validated with campus facility logs. Among retained candidates, only one design satisfies both planning constraints: 400 kWp PV, a 100-kWh BESS, and a 50-kW bidirectional converter operated with a 40% reserve state of charge. Relative to the grid-only case, this design reduces grid purchases by 51.96%, annual maximum apparent demand by 14.49%, and the annual tariff bill by 48.25%. It yields an NPV of TZS 150.58 million, an internal rate of return of 9.57%, and a simple payback of 9.13 years. It achieves 99.87% two-hour survivability and supplies 99.49% of modeled critical energy in the outage-calendar replay. Overall, PV delivers most of the energy and tariff benefit, whereas the BESS is retained primarily for outage readiness; this distinction matters when interpreting the constrained optimum.
-
Article: 79Published: 17.11.2026 pp. 1-12
Green Data Centers: Net-Positive Environmental Impact on Local Ecosystems
AbstractThe rapid expansion of digital infrastructure intensifies the environmental burden of data centers through high energy consumption, freshwater depletion, land-use change, and waste heat emission. Conventional sustainability strategies focusing on efficiency and carbon offsets prove insufficient to address these escalating ecological challenges. This study proposes a transformative net-positive model where data centers actively restore and enhance surrounding ecosystems rather than merely reducing harm. A mixed-methods approach integrating literature synthesis, conceptual modeling, and case study analysis develops a Four-Pillar Framework comprising Energy Synergy, Water Stewardship, Ecological Integration, and Thermal Circularity. To measure performance rigorously across disparate environmental dimensions, we introduce a distance-to-target normalized, non-compensatory Composite Net-Positive Index (CNPI) aggregated via a weighted geometric mean. The model incorporates dynamic Analytic Hierarchy Process (AHP) contextual weighting based on site-specific ecological stressors (θi) and a bounded degradation penalty function for biodiversity impacts. Application to two illustrative cases, a Nordic urban facility and an arid-zone data center, demonstrates CNPI scores of 1.30 and 1.28, respectively, confirming measurable ecological regeneration. This research offers a scalable, interdisciplinary blueprint for transitioning data centers from environmental liabilities to regenerative assets that support climate resilience and biodiversity recovery.
-
Article: 96Published: 17.11.2026 pp. 1-15
Reliability-Oriented Design and Sizing of a Standalone Solar PV-Battery Chick Brooding System under the Cool Highland Climate of Mbeya, Tanzania
AbstractThough the heating need often matches poor or very variable energy access, reliable chick brooding in cold mountain regions calls for constant heat during the first weeks after hatching. For a standalone solar photovoltaic (PV)-battery brooder serving 80 chicks under the climatic conditions of Mbeya, Tanzania, this study created a reliability-oriented design and simulation framework. An age-dependent thermal-load model was matched with a cleaned 2023–2025 dataset comprising 1,096 aligned daily records of maximum temperature, minimum temperature, and sunshine duration. For Week 1, the mean modeled electrical heating demand was 3.73 kWh/day, while the 95th-percentile demand was 5.20 kWh/day. January sunshine of 3.11 h/day and a PV performance ratio of 0.75 yielded a theoretical PV requirement of 2.23 kWp utilizing the conservative design load; the ultimate array was raised to 2.60 kWp. Three-day battery sizing with 24 V, 80% maximum depth of discharge and 90% battery efficiency resulted in 902.78 Ah, hence guiding choice of a 1000 Ah bank. Both PV supply and heating demand were reconstructed hourly and the battery was dispatched chronologically over thirty-six 28-day cycles. Final design reached a mean loss of load probability (LLP) of 0.1087%, a maximum cycle LLP of 3.9130%, a minimum state of charge (SOC) of 20.0% and a mean heating-energy compliance of 99.8913%. Only the January 2024 cycle had 1.589 kWh of significant unmet heating energy. The model thus suggests great technical dependability under the given assumptions; prototype validation is still needed before purchases or field deployment.
Review Articles
-
Article: 80Published: 17.11.2026 pp. 1-17
Hybrid Photovoltaic-Thermal (PVT) Energy Systems for Hotel Operations: A Review of Design Strategies and Implementation Challenges in Tanzania
AbstractTanzania’s hospitality sector faces persistent challenges in providing reliable and affordable hot water because of rising electricity tariffs, grid instability, and reliance on fossil fuel backup systems. Given the country’s high solar irradiance, hybrid photovoltaic (PV) and solar thermal (PV/T) systems are a promising option for increasing thermal energy reliability and reducing operational costs and environmental impacts. This review synthesizes global and regional studies on hybrid configurations that integrate photovoltaic electricity generation with solar thermal water heating technologies, focusing on their relevance to hotel operations in Tanzania. We describe system design approaches, control strategies, storage options, and reported operational outcomes, and we summarize performance ranges (notably reported solar fractions of roughly 60–80% in well-designed systems) and typical techno economic indicators. The evidence indicates that hybrid systems can substantially increase solar contribution to hot water loads and reduce grid dependence, but adoption in Tanzania is constrained by limited local performance data, a lack of standardized design practices, and insufficient techno economic evaluations tailored to local conditions. We conclude that hybrid PV/T systems show strong potential for commercial hot water use in Tanzania and recommend targeted field trials, standardized design guidelines, and context specific economic analyses to support wider deployment.
-
Article: 90Published: 17.11.2026 pp. 1-30
Integrated Solar Photovoltaic and Water Purification Systems for Rural Tanzania: A Review of Technologies and Deployment Barriers
AbstractIn rural Tanzania, unreliable electricity constrains decentralized water treatment. This review evaluates Photovoltaic (PV) powered ultraviolet (UV) disinfection and reverse osmosis/nanofiltration (RO/NF), chlorination, filtration and photocatalysis. A structured narrative search of one engineering database (ScienceDirect) and one academic search engine (Google Scholar) covered 2016–2026. The cited evidence base comprised 45 publications from 2016–2026, three earlier foundational sources and five institutional/report sources (53 sources total). Tanzanian Photovoltaic (PV) powered ultrafiltration–nanofiltration (UF–NF) field tests produced about 1,200 L per solar day at approximately 1.5 kWh/m³; auxiliary air bubbling could add about 0.8 kWh/m³. Tanzania receives about 4–7 kWh/m²/day of solar irradiation, but rainy-season cloud cover can reduce PV output when treatment demand may rise. Filtration plus chlorination is the most deployable near-term pathway. The proposed decision framework integrates source-water type, specific energy consumption (SEC), solar/grid reliability, operator capacity, supply chain and maintenance.
-
Article: 93Published: 17.11.2026 pp. 1-26
Advancing Psychrophilic Anaerobic Digestion of Cattle Manure through Microbial Adaptation, Bioaugmentation and Pathways to Reliable Low-Temperature Biogas: A Critical Review
AbstractLow-temperature anaerobic digestion of cattle manure can recover methane, but slow conversion and delayed start-up can limit reliable energy delivery. This critical narrative review examines biochemical constraints, microbial adaptation and bioaugmentation, performance measurement and translation to useful energy. International evidence is synthesized, with the Ngorongoro Conservation Area of northern Tanzania serving as a motivating application context. The synthesis identifies coordination of hydrolysis, syntrophic conversion and methanogenesis as central to methane onset, production rate and stability. Cold-adapted inocula and targeted consortia can improve methane recovery in selected controlled systems, but differences in substrates, inocula, dosing and reactor operation restrict cross-study comparison and field extrapolation. Combined microbial and carbon amendments require controls that distinguish biological effects from additional substrate contributions. Reliable interpretation also requires explicit solids accounting, gas volume reference conditions and separation of measured recovery from modeled asymptotic potential. Higher methane recovery alone does not establish improved pH stability, methane fraction or microbial persistence. Net energy and economic benefits of these interventions remain insufficiently resolved because methane gains must be assessed alongside process and intervention inputs, gas losses and useful conversion to cooking heat, boiler heat or electricity. Priorities are replicated factorial experiments, integrated monitoring, kinetic validation and seasonal pilot trials linking biological enhancement to measured energy services and locally grounded economic assessment.