Article: 1Published: 30.04.2025 pp. 1-10
A Moving Average Filter based DSTATCOM Control Approach
- 1,141Views 987PDF access
AbstractSelf-excited induction generators (SEIGs) are commonly preferred in stand-alone renewable energy systems due to their low cost and robust construction. However, the voltage and frequency stability at the SEIG output may be adversely affected by varying reactive and active power demands depending on the load profile. In such systems, DSTATCOM is used to provide voltage and frequency regulation, and its performance largely depends on the applied control algorithm. In this study, a moving average filter (MAF) based dq control algorithm is proposed for DSTATCOM supported SEIG systems. The MAF structure contributes to more accurate calculation of reference source currents by reducing the effect of harmonic content. The proposed control method is tested under nonlinear load and unbalanced-nonlinear load conditions. The results show that the system maintains voltage and frequency stability and successfully suppresses disturbances.
-
Article: 2Published: 30.04.2025 pp. 11-32
A Comparative Analysis of Genetic Algorithm Replacement Strategies in a Real-World Optimization Problem: An Elitism and Diversity Oriented Perspective
- 416Views 422PDF access
AbstractIn this study, generation replacement strategies used in genetic algorithms are comparatively analysed in the context of a real-world optimization problem, with a focus on the balance between elitism and diversity. The problem under consideration involves solving the equations of the Selective Harmonic Elimination (SHE) method, which is widely used for controlling Multilevel Inverters (MLIs). Six algorithms, each employing a different replacement mechanism, were tested under four distinct scenarios composed of various population sizes and iteration counts. The results were evaluated using fundamental statistical metrics, boxplots, and convergence curves. The findings reveal that elitist strategies perform better in large-population, long-duration scenarios, whereas approaches prioritizing diversity yield more effective results under limited resource conditions. This study systematically demonstrates the impact of different replacement strategies on optimization performance and offers valuable insights for strategy selection in real-world optimization problems
-
Article: 3Published: 30.04.2025 pp. 33-39
Investigation of the Effects of TiO₂ and Al₂O₃ Nanoparticles on Exhaust Gas Temperature in Direct Injection Gasoline Engines
- 286Views 271PDF access
AbstractIn this study, the effects of Al₂O₃ and TiO₂ nanoparticles on exhaust gas temperature (EGT) in a direct injection gasoline engine were experimentally investigated. The Al₂O₃ and TiO₂ nanoparticles were added to fuel mixtures in concentrations of 3.5 ppm and 7 ppm, and tested at engine speeds of 1500, 2500, and 3500 rpm. The results demonstrate that nanoparticles enhance heat transfer within the combustion chamber, leading to higher combustion temperatures. This translates to greater energy production in terms of combustion efficiency and engine performance. In conclusion, the use of Al₂O₃ and TiO₂ nanoparticles as fuel additives shows potential for improving engine performance and offers a novel approach for controlling exhaust gas temperature.
-
Article: 4Published: 30.04.2025 pp. 40-51
Comparative Analysis of Grid-Following (GFL) and Grid-Forming (GFM) Inverters: Control and Transition Capabilities
- 2,283Views 1,260PDF access
AbstractIn recent years, interest in integration of renewable energy (RE) sources (particularly Wind Energy Systems - WES) into the electrical grid for sustainable, innovative solutions and a greener future continues to grow exponentially. To date, most RE sources have been connected to the grid through traditional grid-following inverters (GFL). Although this control method promises grid compatibility and lower complexity, the unpredictable variability of these eco-friendly RE sources leads to undesirable effects when taken into account. With the increasing interaction of renewable energy sources in today's grid, new challenges arise—such as voltage/frequency regulation and the reduction of overall system inertia—that cannot be resolved with conventional grid-following inverters (GFL). Therefore, the concept of grid-forming inverters (GFM) has been adopted.
The aim of this study is to examine the comparison between grid-forming inverters and traditional grid-following inverters, particularly focusing on droop control, and to regulate the simulated test results with appropriate control systems. For this purpose, the study first compares GFM—based on different control techniques (droop, virtual synchronous generator, and synchronverter control) in the literature—with the conventional GFL technique. The circuit tested in this study involves a 40 kVA-rated inverter supplying relevant loads and the grid, with GFL and GFM control modes analyzed separately. Finally, the potential effects of inverters on load variation and grid outages will be considered.
-
Article: 5Published: 30.04.2025 pp. 52-63
Evaluation of Magnet Demagnetization Behavior in Permanent Magnet Linear Synchronous Motors
- 817Views 963PDF access
AbstractThis paper focus on investigating the demagnetization behavior of permanent magnets in Permanent Magnet Linear Synchronous Motors (PMLSMs) under varying thermal and electrical operation conditions. For this, two complementary Finite Element Method-based approaches are used. The first method utilized magnetostatic analysis to determine the B-H operating points of the magnets under worst-case conditions, allowing the identification of critical regions that tend to move away from the irreversible magnetic field. The second method employed time-domain transient analysis to monitor changes in the induced voltage under varying temperatures and stator current levels. The results revealed that increasing current and temperature significantly reduced the permanent flux density, indicating partial or complete demagnetization. Furthermore, the demagnetization thresholds were shown through safe operating area curves